The following table provides an overview of the menu structure.
Menu overview
Main
menu
Sub-
menu
Description Setting Comment Fac-
tory
set-
tings
10 Signal tone setting
11 Signal tone active if water
tank empty.
00 = OFF
01 = ON
01
12 Signal tone active if UV lamp
defective.
00 = OFF
01 = ON
Only on models with UV tech-
nology.
01
13 Signal tone active on external
water sensor alarm.
00 = OFF
01 = ON
Only on models with external
water sensor.
01
14 Signal tone active if fill amount
of water tank 50 liters (13.2
gallons).
00 = OFF
01 = ON
Only on models with automatic
water supply.
01
15 Signal tone active during
missing radio signal.
00 = OFF
01 = ON
01
20 Relay setting The relay settings are only
required when connected to a
central air-conditioning moni-
toring system.
00
21 Relay active if water tank
empty.
00 = OFF
01 = ON
00
22 Relay active if UV lamp defec-
tive.
00 = OFF
01 = ON
00
23 Relay active on external water
sensor alarm.
00 = OFF
01 = ON
00
24 Relay active if fill amount of
water tank 50 liters (13.2
gallons).
00 = OFF
01 = ON
00
25 Relay active during missing
radio signal.
00 = OFF
01 = ON
00
Operating the humidifier
Evaporation Humidifier B500 Professional36