Main
menu
Sub-
menu
Description Setting Comment Fac-
tory
set-
tings
30 General settings
31 Flush cycle in days. 00 = OFF
(manual)
01 ... 07
days
Only on models with flushing
unit.
07
32 Setting the water hardness. 01 = soft
02 = medium
03 = hard
The water hardness affects the
interval of the filter replacement
indication.
02
33 Number of days until the filter
needs to be replaced.
0 - 98 =
Number of
days
The filter replacement indicator
shows in how many days the
filter will need to be replaced
(0-98 days). After replacing the
filter, the value must be set
manually back to 98.
98
34 Operation via external timer or
other 230 V switch-on mecha-
nism.
00 = OFF
01 = ON
Humidity target value is set to
90%. The actual value con-
stantly shows 00%. The fan
setting is freely selectable.
00
35 Adjustment/control interval of
fan during automatic opera-
tion.
01 ... 10 min. Depending on room size. 05