Personnel:
n
Licensed plumber
Connect the automatic flushing device to the waste water
system as per the regulations of the local water supply
authority. When doing so, observe the following points:
n The material used and the connection must meet the IEC
61770 standard.
n The waste water hose may not be longer than 1.5 meters
(5 feet), since the pump only has a certain output and
otherwise no pressure is built up.
n Ensure that the waste water hose is not routed up an
incline.
n To fill the water column, if necessary, fill the hose with
water prior to connection.
n To prevent the formation of a vacuum, equip the line with
a bleeder if required.
n For dimensions and connection sizes, see drawing
Fig. 58.
Fig. 58: Automatic flushing device
8.4 Activated charcoal cleaning filter
8.4.1 Overview
Order number: 1605/500
Accessories
Evaporation Humidifier B500 Professional 63