To prevent overfilling, the device switches off automatically upon
reaching a fill level of 50 liters (13.2 gallons). Here, an acoustic
warning signal sounds and error code 04 appears on the display. If
there is a defect in the water supply and the water level does not
change after 10 minutes despite the solenoid valve being open, the
operation is cancelled and error code 01 appears on the display.
The following information is directed exclusively to
licensed plumbers who connect the humidifier to the
local water supply system.
NOTICE!
Risk of property damage due to excessive water
pressure!
The humidifier could be damaged if the water pressure
of the local water supply system is too high.
– The maximum water pressure may not exceed 1
MPa (145 psi).
Personnel:
n
Licensed plumber
1. To prevent contamination of the solenoid valve, thoroughly
flush the line prior to connecting.
2. Connect the humidifier to the local water supply system as
per the regulations of the local water supply authority. When
doing so, observe the following points:
n The material used and the connection must meet the IEC
61770 standard.
n Only use new hoses. Used hoses may not be used
again.
n Always observe the regulations of the local water sup-
plier. A backflow preventer may be required.
n For a diagram with the dimensions of the connection, see
Fig. 58.
8.3 Automatic flushing device
Order number: 1740
Safety devices
Information for licensed plumbers
Accessories
Evaporation Humidifier B500 Professional 61