Battery Controller / Hourmeter / Lift Interrupt
PS S5.3 5230
F-code Section C-code
Version no T-code
001
© BT Products
151
Service Manual 1997-04-15
L-M means that you adjust on the line between L and M.
N-O means that you adjust on the line between N and O.
An hydrometer can be used for precise adjustment. When the
bottom two LEDs are flashing on and off the specific gravity of
the battery electrolyte should not be lower than 1.14. If they
start to flash at higher specific gravity the discharge U
potentiometer should be turned counterclockwise (towards
K). If the two LEDs start to flash at a specific gravity below
1.14 turn the potentiometer clockwise (towards P).
The letter designations for the voltage per cell (VPC)
multipliers at empty battery are specified as tabulated below
.
Battery Ah
180 L-M
210 M-N
240 N-O
SETTING VPC SETTING VPC
K1.57 P1.82
L1.63 Q1.84
M1.68 R1.86
N1.73 S1.91
O1.78 T1.93
PIN NO: FUNCTION
1 Hourmeter (-)
2 Key switch (+)
3 Relay arm (+)
4 Relay NC (-)
5 Battery (-)
6 Hourmeter (+)
7 24 Volt (+)
8 48 Volt (+)
DISCHARGE
N
M
L
K
O
P
Q
R
S
T
1234
5678
Return