238
Service Manual 1997-09-15
6.13. Function 17
Card Type Selection (Push CONT and 2)
This function allows for the selection of the card type used for
your vehicle's application. The table below shows the setting
to select card application type depending on which control
card is used.
Settings for these functions should be made in between the
values shown.
EV100 Standar Speed
Function with F Limit Regen/FW
STD C/L 0 to 4 20 to 24 40 to 44
High C/L 5 to 9 25 to 29 45 to 49
STD C/L
(Auto plug) 10 to 14 30 to 34 50 to 54
High C/L
(Auto plug) 15 to 19 35 to 39 55 to 59
EV200 Standar Speed
Function with F Limit Regen/FW
STD C/L 64 to 68 84 to 88 104 to 108
STD C/L
(Auto plug) 74 to 78 94 to 98 114 to 118
These settings must be changed by
authorized personnel only, following
instructions supplied by the manufacturer.
Card type selection must be made within
the capabilities of the SCR control panel
used and the supporting electro-
mechanical devices. Failure to comply with
proper application standards could result
in mis-operation or damage to the control
and/or motors.
WARNING