EasyManua.ls Logo

BT OE35 - Page 68

BT OE35
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PS S1.0 1700
001
Version no T-code
F-code Section C-code
Drive Motor
66
Service Manual 1997-07-15
Rapid commutator
wear with bright surface
copper dragging
Foreign material in brush face
Wrong brush grade
Brush vibration
43-45-47-49
61
39-52-58-59
Indications Appearing as Heating
Indications Immediate Causes Primary Faults
Heating in windings Severe load condition
Unbalanced magnetic field
Unbalanced armature
currents
Poorly equalized parallel
operation lack of ventilation
38-41-42-53
18-19-20-21-27-28-29
8-19-22-25-27-28-29-37
7-13-23-24
Heating at commutator Severe load condition
Severe sparking
High friction
Poor commutator surface
Depreciation
High contact resistance
38-41-42
7-8-9-12-20-33-45-57
10-11-36-43-45-49-58-59
See specific surface fault in
evidence
6-24
56
Heating at brushes Severe load condition
Faulty machine adjustment
Severe sparking
Raw streaks on commutator
surface
Embedded copper
Wrong brush grade
38-41-42
7-10-11-12-26
See “Sparking
See “Streaking or threading of
surface”
See “Copper in brush face”
57-58-59-61-62
Return

Table of Contents

Related product manuals