Cleaning, maintenance and servicing
V-Mix Fix Plus
109165
Translation of original operating manual
95
7.8.2 Hydraulic aggregate 1.1 KW (optional)
WARNING
Hazards to personnel due to slipping and falling can occur in the event of oil leaks
when oil is added or changed!
Promptly clean new oil spots with binding agents.
7.8.2.1 Hydraulic aggregate 1.1 KW maintenance plan
Inspection and maintenance schedules
One time
Serial operation
After 100
hours
daily
monthly
annually
Hydraulic oil
Version
X
Temperature (max.
70°C)
X
Change
X
X
Filter
Replace/inspect filters
that have no contamina-
tion indicator
X
X
Settings
Pressure relief valve
X
X
Other checks
Leakage to the outside
X
Contamination
X
Tightness of all screws
X
X
Noise
X
7.8.2.2 Monitor the level of hydraulic oil hydraulic aggregate 1.1 KW
Check the level of hydraulic oil daily at the start of each workday.
1. Read off the level of hydraulic oil from the mark-
ing under the ventilated oil filler plug (1).
2. The hydraulic oil level should be filled up to the
upper oil level mark. If the oil level is low, fill with
hydraulic oil - refer to Chapter „Replenish hy-
draulic oil Hydraulic aggregate 1.1 KW“, page 96.
Fig. 7-18 Hydraulic aggregate
1