72
NICE - MIRIAM - CRISTAL - LEONORA - PRETTY - DIANA - KRISS - MARY
EN
11.4 ”HOT FUME” ALARM
If the fume probe registers a temperature at the exhaust higher then 180°C, the display shows “HOT FUME”.
Then the combustible (pellet) drop will be decreased at phase 1.
This function has the aim to bring the values within preset values. If for any reason the temperature would
not decreas but increase, at 215°C the display shows “ACTIVE ALARM” “AL 3 - HOT FUME” and the stove
start the switching off phase up.
Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and the is in “OFF”.
Check the type of glitch as ALARMS page 79.
Clean the burning pot and start the stove up again with P4 key.
11.5 ”FAN FAILURE” ALARM
“ACTIVE ALARM” “AL 4 - FAN FAILURE”: the fume fan is out of order.
Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and the is in “OFF”.
Check the type of glitch as ALARMS page 79.
Clean the burning pot and start the stove up again with P4 key.
11.6 ”FAILED IGNITION” ALARM
“ACTIVE ALARM” “AL 5 - FAILED IGNITION”: the temperatureis not sufcient for ignition.
Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and the is in “OFF”.
Check the type of glitch as ALARMS page 79.
Clean the burning pot and start the stove up again with P4 key.
11.7 ”NO PELLET” ALARM
If the fume probe registers a temperature at the exhaust lower than the minimum threshold and the display
shows “ACTIVE ALARM” “AL 6 - NO PELLET”.
Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and the is in “OFF”.
Full the hopper.
Clean the burning pot and start the stove up again with P4 key.
11.8 ”THERMAL SAFETY” ALARM
In the hopper is installed a thermostat with manual reset which activates if the temperature excursion
exceeds the allowed limits, so avoiding the possibility that the pellet inside the hopper could burn because
of overheating.
“ACTIVE ALARM” “AL 7 - THERMAL SAFETY”: the thermostat stops the power supply to the auger.
Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and then is in “OFF”.
Check the type of glitch as ALARMS page 79.
Unscrew the black cap, press the button and screw the cap again.
Clean the burning pot and start the stove up again with P4 key.
11.9 ”FAILURE DEPRESS” ALARM
To the boiler is connected a pressostat which control the depression and in some stove models on the re
door id installed a microswitch which registers the opening.
“ACTIVE ALARM” “AL 8 - FAILURE DEPRESS”: the pressostat and/or re door which is not correctly closed
stops the power supply to the auger.
Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and then is in “OFF”.
Check the type of glitch as ALARMS page 79.
Unscrew the black cap, press the button and screw the cap again.
Clean the burning pot and start the stove up again with P4 key.