If the auger is blocked by a foreign object (for example: nails), and if it needs to be
cleaned, DO NOT remove the hand rejector and DO NOT touch the auger. Please
contact the stove manufacturer or the Technical Assistance service of the stove
manufacturer.
The hand rejector can be removed exclusively by an authorized technician.
12.4 FUME CHAMBER CLEANING
Every 4/8 weeks the fume chamber cleaning must be executed.
Fig. 32 - Fume chamber Fig. 33 - Fume chamber cleaning
Unscrew the 2 fume chamber closing zincate panel screw which stands on the back of the stove (see
Fig. 32 page 75).
Clean with a vacuum cleaner the ash which has accumulated on the inner (see Fig. 33 page 75).
After the cleaning the opposite operation is to repeat checking the gasket efciency and integrity: if
necessary provide for its replacement by an Authorized Technician.
12.5 FUME CONDUIT CLEANING
The exhaust system must be cleaned every month.
Fig. 34 - Fume conduit cleaning
Remove the inspection lid of the T-union (see Fig. 34 page 75).