CALIENT OCS WebGUI Quick Start Guide
Doc. Part No. 460185-00
July 28, 2015
Rev. 0.2
Page 26 of 63
5. Click the Save button at the bottom of the screen to save any changes, or click the Reset
button to clear them.
4.2 Node > Summary > Alarm Config
The following steps describe how to configure system alarms using the WebGUI:
1. Log into the WebGUI.
2. Navigate the following path: Node > Summary > Alarm Config. The Alarm Configuration
screen will open.
3. Type a value in the Soak Interval: field to specify the length of time, in seconds, a
condition must persist before the system commits it as an alarm. If the condition clears
within the specified soak interval, an alarm will not be generated for it.
4. Click the down arrow () at the right of the Change To field for any listed alarm to
display a dropdown menu.