1
p. 4 - Manual FA00442-EN - 12/2017 - © CAME S.p.A. - Translated original instructions
WHAT TO DO IF ...
ISSUES
POSSIBLE CAUSES POSSIBLE FIXES
It neither opens nor closes • Power supply is missing
• The gearmotor is stuck
• The transmitter is emitting a weak signal or no signal at all
• Control buttons or selectors stuck
• Check main power supply
• Lock the gearmotor
• Replace the batteries
• Check the state of all devices
The gate opens but does not
close
• The photocells are working • Check that there are no obstructions in the
photocells' area of operation
⚠ If the problem cannot be solved by following the fixes in the table or if any malfunctions, anomalies, noises, vibrations or suspicious and unexpected
behavior is experienced on the system, call for qualified assistance.
MAINTENANCE
⚠
WHEN CLEANING, MAINTAINING AND REPLACING PARTS, DISCONNECT THE OPERATOR FROM THE MAINS
POWER SUPPLY (EXCLUDING POINT B)
At least every six months, perform ordinary maintenance jobs.
⚠ When performing this procedure, keep clear of the movement of the boom.
A - Wipe clean the photocells' glass with a soft, slightly water-dampened cloth. Do not use any solvents or other chemicals.
B - Check that the photocells are working properly by waving an object between them when the gate is moving: is the gate inverts its
direction or the maneuver is stopped, the photocells are working properly.
C - Check that there are no impediments to the proper operation of the operator, such as any overgrown vegetation that could block the
photocells or any changes or yielding to the gate's structure.
Any repairs, or changes to the installation must be performed by qualifi ed sta and all jobs logged carefully.
MANUALLY RELEASING THE GEARMOTOR
⚠ Manually releasing the gate may cause an uncontrolled movement of the gate due to possible mechanical anomalies or
unbalancing.
RELEASING (fi gure )
- Refi t the trilobe key and turn it clockwise.
- Open the hatch and turn the supplied release handle counterclockwise.
LOCKING (fi gure )
To lock the operator back into place, turn the handle clockwise and close the hatch, then turn the key counterclockwise.