What causes high head pressure in a Carrier C708 Freezer?
J
Jonathan WilsonAug 27, 2025
High head pressure in your Carrier Freezer can be caused by:
* A dirty condenser. Clean the condenser.
* A water valve that is out of adjustment or restricted. Check the adjustment and the water supply.
* Insufficient air space around the unit. Ensure sufficient air space surrounds the unit (see “Specifications”).
* Refrigerant overcharge. Correct the refrigerant charge.
* A faulty blower. Replace the blower.
D
David FowlerAug 27, 2025
How to fix a Carrier C708 Freezer with no operation in any mode?
A
Andrew DuffyAug 27, 2025
If your Carrier Freezer isn't operating in any mode, check these potential causes:
* The unit might be unplugged. Ensure it is plugged in.
* The circuit breaker could be turned off, or the fuse might be blown. Turn on the circuit breaker or replace the fuse.
* The power switch may be in the “OFF” position. Place the power switch in the “ON” position.
E
Eric KempAug 25, 2025
Why is the product from my Carrier C708 Freezer too soft?
J
John WalkerAug 26, 2025
If the product from your Carrier Freezer is too soft, consider the following possibilities:
* Insufficient air space around the unit. Allow 6” (152 mm) minimum clearance around both sides of the unit and place the back against a wall.
* Worn scraper blades. Replace the scraper blades.
* Dirty air-cooled condenser. Clean monthly.
* Outdated mix. Use fresh mix.
* Refrigerant shortage. Locate leak and repair.
* Product viscosity set too warm. Adjust product viscosity.
* Incorrect usage of the mix feed tube (C709/C717). Follow the correct feed tube procedures and use of the air orifice.
* Incorrect DBV setting. See “Checking and Setting Refrigeration Valves.”