CHAPTER 6 – LUBRICATION / FILTERS / FLUIDS
6-35
Each 500 hours
WARNING: Never use gasoline, solvent or
other ammable uids to clean parts. Use au-
thorized commercial, nonammable, nontoxic
solvents.
Clean lter and surrounding area. Then remove the lter
housing, change the elements and gaskets. Clean the
inside of the lter housing and contact surface. Install
the new lter.
Lubricate the lter seal with a thin coat of clean uid and
tighten the new lter until it contacts with the sealing sur-
face. Tighten the lter 1/3 to 1/2 a turn more.
ATTENTION: Dispose used lters in speciali-
zed recycling stations.
ZF TRANSMISSION FLUID FILTER
(845B / 865B / 885B WITH ZF TRANSMISSION)
FUNK TRANSMISSION FLUID FILTER
(845B / 865B / 885B WITH FUNK TRANSMISSION)
Transmission Fluid Filter Change