REMOVAL FROM STORAGE
A loader taken out of storage must havethe following done before being
placed in operation.
NOTE:
Do not start the engine until items 1-8 below havebeen done.
1. If cooling system has beendrained for storage, refill with clean, soft water
and with permanent type antifreeze.
2. Make sure the engine oil is at the required level.
3. Reinstall the batteries, fully charged.
4. A fuel tank protected from rust by VPI 260crystals has only to be refilled
with clean, water-free NO.2 diesel fuel.
5. Check tires for correct air pressure.
6. Close the draincock on the bottom of both air reservoirs.
7. Tighten the dipstick/filler cap on top of the hydraulic reservoir. Besurethe
air shutoff valve, above the reservoir, is turned on so that the tank is
pressurized.
8. Check all controls for freedom of movement making surethey do not stick.
9. Change the fuel filters and bleed the fuel system.
NOTE:
If machine is equipped with a turbocharger, refer to page 53for
procedure to start the engine.
10. Start the engine and run at idling speed, 700-750 rpm. It is advisable to
removethe valvecoverto makesurevalvesare not sticking and the rocker
arm assembly is being lubricated. The flushing oil in the fuel system will
causeablue-white exhaust smokefor ashort time; this will not damagethe
engine.