WELDSKILL 250, 350 DISASSEMBLY pROCEDURE
Disassembly Procedure
8 Manual 0-5186
7.06 Power Switch S1 and Power Cord Removal
!
Read and follow safety information in Section 6.02 before proceeding with disassembly
1. Gas inlet. Remove gas inlet from rear panel.
2. SW1 locking tabs
Squeeze the locking tabs and push SW1 out from the rear panel.
3. Strain relief screws
Remove the two (2) screws from the strain relief.
4. Remove Fan.
5 Input Power Cord ground wire filter.
Cut the tie-wrap and remove the Ferrite core from the ground wire.
6. Pull the Input Power Cord out. It may be necessary to use a flat blade screw driver against the strain
relief tabs, prying outward (Internal side if strain relief) to help remove the cord.
1
2
3
Art # A-10207