Page no. 23
Battery:
Type: Lithium.
Life: 10 years.
Operation without battery
nor voltage:
Maximum 96 hours
Clock:
Type: Quartz oscillator/Mains frequency
Margin: < 0.5 s per day at 25 ºC
Inputs: Free of potential: 60-300 V. AC.
Digital outputs: Free of potential
Type: Mechanical, optoMOS (According to model)
LED outputs
Maximum cadence: 20000 pulses / kW.h or kvar.h
1000 pulses /kW.h or Kvrh. (direct measurement)
Safety: Category III (110 V) according to EN-61010
Assembly features:
Casing: According to DIN 43859 Standard
Size:
According to DIN 43857 Standard
Optical Reader:
Protocols:
IEC-61107 for on-site access.
Series port (According
to model):
RS-232 or RS-485 CHANNEL
Tests/Standards:
EN 60687
EN 61036
EN 61268
Standards on static, active energy meters for alternating
current, class 0.5S and 1.0.
Standards on reactive energy static meters for alternating
current class 2.0 and 3.0.
EN 55022 Conducted emissions: Class B
Radiated emissions: Class B
EN 61000-4-6 Immunity to RF fields joined to cables (common mode): 10 V