3A-6 P/N 11934-004
Section 3A Cirrus Design
Abnormal Procedures SR20
Fuel System (Cont)
Fuel Filter in Bypass Mode
FUEL FILTER Advisory
The fuel filter is in bypass mode. The fuel filter element must be
replaced.
1. If In-Flight..................................LAND AS SOON AS PRACTICAL
2. Replace fuel filter element prior to next flight.
Electrical System
Battery 1 Current Sensor
BATT 1 Caution
Battery 1 current is discharging at a rate greater than 4 amps for 30
seconds or more.
1. Land as soon as practical.
FUEL FILTER
BATT 1
Original Issue