VSAN: 200, State: Up
VSAN: 400, State: Up
VSAN: 20, State: Up
VSAN: 100, State: Up
VSAN: 300, State: Up
VSAN: 500, State: Up, FCID: 0xa10000
Interface: fc2/6, State: Trunking
VSAN: 1, State: Up
VSAN: 200, State: Up
VSAN: 400, State: Up
VSAN: 20, State: Up
VSAN: 100, State: Up
VSAN: 300, State: Up
VSAN: 500, State: Up, FCID: 0xa10001
Interface: vfc90, State: Down
Interface: vfc100, State: Down
Interface: vfc110, State: Down
Interface: vfc111, State: Down
Interface: vfc120, State: Down
Interface: vfc130, State: Trunking
VSAN: 1, State: Waiting For VSAN Up
VSAN: 200, State: Up
VSAN: 400, State: Up
VSAN: 100, State: Up
VSAN: 300, State: Up
VSAN: 500, State: Up, FCID: 0xa10002
Number of External Interfaces: 8
Server Interfaces:
==================
Interface: vfc1, VSAN: 20, State: Up
Interface: vfc2, VSAN: 4094, State: Down
Interface: vfc3, VSAN: 4094, State: Down
Interface: vfc5000, VSAN: 4094, State: Down
Interface: vfc6000, VSAN: 4094, State: Down
Interface: vfc7000, VSAN: 4094, State: Down
Interface: vfc8090, VSAN: 4094, State: Down
Interface: vfc8191, VSAN: 4094, State: Down
Number of Server Interfaces: 8
This example shows the running configuration of port channel 130:
switch# show running-config interface port-channel 130
!Command: show running-config interface port-channel130
!Time: Wed Jan 30 22:01:05 2013
version 6.0(2)N1(1)
interface port-channel130
switchport mode trunk
switchport trunk native vlan 2
no negotiate auto
This example shows the impact of FCoE NPV on an ISSU:
switch# show fcoe-npv issu-impact
show fcoe-npv issu-impact
-------------------------
Please make sure to enable "disable-fka" on all logged in VFCs
Please increase the FKA duration to 60 seconds on FCF
Active VNP ports with no disable-fka set
----------------------------------------
vfc90
vfc100
vfc110
vfc111
Cisco Nexus 5500 Series NX-OS SAN Switching Configuration Guide, Release 7.x
80 OL-30895-01
Configuring FCoE NPV
Configuration Examples for FCoE NPV