Persistent FC ID Selective Purging
Persistent FC IDs can be purged selectively. Static entries and FC IDs currently in use cannot be deleted. The
table below identifies the FC ID entries that are deleted or retained when persistent FC IDs are purged.
Table 7: Purged FC IDs
ActionPersistent Usage StatePersistent FC ID state
Not deletedIn useStatic
Not deletedNot in useStatic
Not deletedIn useDynamic
DeletedNot in useDynamic
Purging Persistent FC IDs
You can purge persistent FC IDs.
Procedure
PurposeCommand or Action
Purges all dynamic and unused FC IDs in
the specified VSAN.
purge fcdomain fcid vsan vsan-id
Example:
switch# purge fcdomain fcid vsan 667
Step 1
Purges dynamic and unused FC IDs in the
specified VSAN range.
purge fcdomain fcid vsan vsan-id - vsan-id
Example:
switch# purge fcdomain fcid vsan 50-100
Step 2
Verifying the fcdomain Configuration
If the fcdomain feature is disabled, the runtime fabric name in the display is the same as the configured
fabric name.
Note
This example shows how to display information about fcdomain configurations:
switch# show fcdomain vsan 2
Cisco Nexus 5500 Series NX-OS SAN Switching Configuration Guide, Release 7.x