EasyManua.ls Logo

Cisco Nexus 5500 Series NX-OS - Importing and Exporting Zone Sets; Zone Set Duplication

Cisco Nexus 5500 Series NX-OS
320 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Manually resolve the conflict by editing the full zone set, activating the corrected zone set, and then
bringing up the link.
Figure 35: Importing and Exporting the Database
Importing and Exporting Zone Sets
You can import or export the zone set information from or to an adjacent switch.
Procedure
PurposeCommand or Action
Imports the zone set from the adjacent switch connected
through the specified interface for the VSAN or range of
VSANs .
switch# zoneset import interface fc
slot/port vsan vsan-id
Step 1
If this is a QSFP+ GEM, the slot/port syntax is
slot/QSFP-module/port.
Note
Exports the zone set to the adjacent switch connected
through the specified VSAN or range of VSANs.
zoneset export vsan vsan-id
Example:
switch# zoneset export vsan 5
Step 2
Zone Set Duplication
You can make a copy and then edit it without altering the existing active zone set. You can copy an active
zone set from the bootflash: directory, volatile: directory, or slot0 to one of the following areas:
To the full zone set
Cisco Nexus 5500 Series NX-OS SAN Switching Configuration Guide, Release 7.x
142 OL-30895-01
Configuring and Managing Zones
Zone Set Duplication

Table of Contents