EasyManuals Logo

Cisco SG220-26P Administration Guide

Cisco SG220-26P
289 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #80 background imageLoading...
Page #80 background image
Administration: Diagnostics
Configuring Port and VLAN Mirroring
Cisco 220 Series Smart Switches Administration Guide Release 1.1.0.x 78
7
To configure port and VLAN mirroring:
STEP 1 Click Administration > Diagnostics > Port and VLAN Mirroring.
STEP 2 If your switch supports the RSPAN VLAN feature, enter the following information:
RSPAN VLAN—Check Enable to enable RSPAN VLAN mirroring.
RSPAN VLAN ID—Select the VLAN to be mirrored. When you configure a
RSPAN mirroring session, you should select this VLAN as the RSPAN VLAN.
STEP 3 Click Add to add a SPAN or RSPAN mirroring session.
STEP 4 Enter the following information:
Session ID—Select the identifier for the mirroring session.
Session Type—Select one of the following options:
-
Local Port Based
—Copies TX, RX, or both TX and RX traffic from each
port to the destination port.
-
Local VLAN Based
—Copies traffic from the local VLAN to the destination
port.
-
RSPAN Source Session
—Utilizes a VLAN to copy traffic from a source
port or a source VLAN to another device.
-
RSPAN Destination Session
—Utilizes a VLAN to copy traffic from a
destination port to another device.
STEP 5 If Local Port Based is selected, enter the following information:
Destination Port—Select the analyzer port to where packets are copied. A
network analyzer, such as a PC running Wireshark, is connected to this port.
Allow Ingress Packets—Check Enable to allow the destination port to send
or receive normal packets.
Source Port—Select the source ports from where traffic is mirrored and the
type of traffic to be mirrored to the analyzer port. The options are:
- Rx Only—Port mirroring on incoming packets.
- Tx Only—Port mirroring on outgoing packets.
- Tx and Rx—Port mirroring on both incoming and outgoing packets.
- N/ATraffic from this port is not mirrored.

Table of Contents

Other manuals for Cisco SG220-26P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG220-26P and is the answer not in the manual?

Cisco SG220-26P Specifications

General IconGeneral
ModelSG220-26P
Ports26
PoE Ports24
Switching Capacity52 Gbps
Forwarding Rate38.69 Mpps
LayerLayer 2
Power SupplyInternal
VLANs Supported256
ManagementWeb-based GUI, SNMP
Operating Temperature0°C to 40°C
Storage Temperature-4°F to 158°F (-20°C to 70°C)
Operating Humidity10% to 90% non-condensing
Storage Humidity5% to 95% non-condensing
Dimensions440 x 44 x 257 mm
Weight3.3 kg

Related product manuals