— 113 —
GS ^ n1 n2 n3
[Function] Executing the macro
[Code] <1D>H<5E>H<n1><n2><n3>
[Range] 0
n1 255
0
n2 255
0
n3 1
[Outline] Executing contents defined in macro.
n1 : The number of times of macro execution
n2 : Waiting time on macro execution
Waiting time of n2 × 100 msec is given for every execution.
n3 : Macro execution mode
n3=0 Continuous execution:
The Macro is executed “n1” times continuously at the
time interval specified by “n2”.
n3=1 Execution by FEED Switch:
After waiting for the time specified by “n2”, the
ARARM LED flickers and the FEED switch is waiting to
be pressed. When it is pressed, the macro is executed
once. This action is repeated “n1” times.
[Caution] When this command is received while in macro definition,
suspension of macro definition is indicated. At this time, the
defined content is cleared.
No execution takes place when the macro is held undefined
or n1=0.
While in macro execution with n3=1, paper feed with the FEED
switch is not available.
[Default] The initial value is not defined.
[See Also] GS :
[Sample Program] Refer to Sample Program and Print Results for GS: on page
101.