ID-FLX Lite & Telecom Global Guide
145
Setpoint group Engine protection Related FW 2.5.0
Range [units] 0 .. 10000 [U16]
Default value 10 -
Step 1
Comm object 13369 Related applications
Description
High ShutDown limit level for AIN4.
AIN4 HighSd
6 back to List of setpoints
Setpoint group Engine protection Related FW 2.5.0
Range [units] 0 .. 3600 [s]
Default value 10 -
Step 1
Comm object 13370 Related applications
Description
High level protection delay for Wrn and Sd of AIN4.
Note: Analog input 4 is fully configurable and it is voltage type of input with range 0-40 V.
AIN4 HighDel
6 back to List of setpoints
Setpoint group Engine protection Related FW 2.5.0
Range [units] 0 .. 10000[U17]
Default value 20 -
Step 1
Comm object 9274 Related applications
Description
Warning limit level for AIN5.
AIN5 Level 1
6 back to List of setpoints
Setpoint group Engine protection Related FW 2.5.0
Range [units] 0 .. 10000 [U17]
Default value 10 -
Step 1
Comm object 9275 Related applications
Description
Shutdown limit level for AIN5.
AIN5 Level 2
6 back to List of setpoints