EasyManuals Logo
Home>ComAp>Controller>InteliDrive Lite

ComAp InteliDrive Lite Global Guide

ComAp InteliDrive Lite
225 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #156 background imageLoading...
Page #156 background image
ID-FLX Lite & Telecom Global Guide
156
Setpoint group Engine protection Related FW 2.5.0
Range [units] 0 .. 180 [s]
Default value 10 -
Step 1
Comm object 9270 Related applications
Description
Delay for Wrn/Sd AIN9 alarm.
Note: Analog input 9 is configurable with basic two levels protection and it is voltage type of input with
range 0-10V.
AIN9 Del
6 back to List of setpoints
Setpoint group Engine protection Related FW 2.5.0
Range [units] 0 .. 65535 [h]
Default value 10000 YES
Step 1
Comm object 9648 Related applications
Description
Counting down when engine is running, from the moment of setting up the value of working hours in
LiteEdit/controller. This value is counting and changing in LiteEdit/controller as well. Service time alarm
appears if reaches zero, until non-zero value is set.
Note: Set the NextServTime = 65535h to disable count down. The setpoint stays constant, but
Statistics value (visible in LiteEdit) displays #### invalid value.
NextServTime
6 back to List of setpoints
Setpoint group Engine protection Related FW 2.5.0
Range [units] 0.0 .. 5.0 [RPM]
Default value 0.0 -
Step 0.1
GearBoxRatio

Table of Contents

Other manuals for ComAp InteliDrive Lite

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ComAp InteliDrive Lite and is the answer not in the manual?

ComAp InteliDrive Lite Specifications

General IconGeneral
BrandComAp
ModelInteliDrive Lite
CategoryController
LanguageEnglish

Related product manuals