Technical characteristics
Power supply voltage 24 Vdc ± 5%
Absorption 35 mA
Max. CT input cable length 2 m
Inputs 1 for connection of the CT current transformer (supplied), ideal for single-phase lines up to 10 kW
1 for line voltage (230 Vac)
Indications 1 bus status LED: when fl ashing, indicates data transmission via bus
Terminals removable
Positioning On DIN rail or in junction boxes
Approvals CE
Operating temperature 0° to 50°C
Storage temperature -10° to +70°C
Relative air humidity 5 to 95% with no condensation
Accessories included CT current transformer
Weight 70 g, not including CT and packaging
Dimensions 35x90x58 mm (3 DIN modules)
BUS SimpleHome
KWh
D+ -
LNV-IT
CONNECTION TERMINALS
Terminal Function
- BUS power supply negative
+ BUS power supply +24 Vdc
D BUS data line
V- IT Input for non-polarised toroid connection
L N Line voltage connection
32