To modify the con guration of a previously archived system, proceed as follows:
1) while the system is running and connected to the PC via the SIMPLEHOME/RS232 interface, click the “OPEN INSTALLATION” command
on the main screen;
2) at this point the "tree menu screen" will appear, showing the current programming: click on the module you wish to reprogram and the device
con guration window will appear;
3) change the settings as desired and return to the rst of the screens relating to device parameters ("General parameters"): at this point click
"Save", then "Send to module". Wait for the programming to complete, indicated by the progress status bar, and click "Exit".
N.B. this procedure can be used to recon gure the module parameters, with the exception of the serial number; to change this, you will need
to use the "SERIAL NUMBER PROGRAMMING" command.
To modify the con guration of a system for which you do not possess the project le, proceed as follows:
4) while the system is running and connected to the PC via the SIMPLEHOME/RS232 interface, click the “NEW INSTALLATION”
command
on the main screen;
5) a window requesting system data will appear. To continue, you must ll in all the elds (these are required to make the system unique and
traceable). At this point, if everything has been entered correctly, con rm by clicking "Create", or cancel everything and return to the main
screen by clicking "Exit". If the data is con rmed, the "tree menu screen", described in the chapter "TREE MENU SCREEN AND MODULE
PROGRAMMING", will appear. N.B. the tree will appear empty with no devices connected;
6) click the "Exit" button to return to the main screen;
7) click the "Query modules" button;
8) click the "Query modules" button in the window that appears;
the con guration of devices in the system is loaded onto the software, indicated by a progress status bar. The con guration of devices in the
system will be deleted;
9) once con guration reading is complete, click the "OPEN INSTALLATION" button, select the name of the system created previously and click
"Open";
10) at this point the "tree menu" screen showing the current programming will appear, from which the con guration can be modi ed and the
devices programmed as indicated in the paragraph " TREE MENU SCREEN AND MODULE PROGRAMMING".
N.B. this procedure can be used to recon gure the module parameters, with the exception of the serial number; to change this, you will need
to use the "SERIAL NUMBER PROGRAMMING" command.
63