3-5
Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide
POST Error Messages
Continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem
Recommended Action
162-System Options
Not Set
2S Configuration incorrect. Run the System Configuration Utility
and correct.
163-Time & Date
Not Set
2S Invalid time or date in
configuration memory.
Run the System Configuration Utility
and correct.
170-Expansion
Device Not
Responding
None EISA or PCI expansion board
failure.
Check board for secure installation.
Replace the failed board if necessary.
172-Configuration
Nonvolatile Memory
Invalid
None Nonvolatile configuration
corrupt or jumper installed.
Run the System Configuration Utility
and correct.
172-1 Configuration
Nonvolatile Memory
Invalid
None Nonvolatile configuration
corrupt.
Run the System Configuration Utility
and correct.
172-2 IRC
Configuration Invalid
None IRC enabled and video
controller is in PCI slot on the
secondary bus.
Move video controller to a PCI slot on
the primary PCI bus.
173-Slot ID
Mismatch
None Board replaced, configuration
not updated.
Run the System Configuration Utility
and correct.
174-
Configuration/Slot
Mismatch Device
Not Found
None EISA or PCI board not found. Run the System Configuration Utility
and correct.
175-
Configuration/Slot
Mismatch Device
Found
None EISA or PCI board added,
configuration not updated.
Run the System Configuration Utility
and correct.
176-Slot with Not
Readable ID Yields
Valid ID
None EISA or PCI board in slot that
should contain an ISA board.
Run the System Configuration Utility
and correct.
177-Configuration
Not Complete
None Incomplete System
Configuration.
Run the System Configuration Utility
and correct.
178-Processor
Configuration Invalid
None Processor type or step does not
match configuration memory.
Run the System Configuration Utility
and correct.
179-System
Revision Mismatch
None A board was installed that has a
different revision date.
Run the System Configuration Utility
and correct.
180-Log Reinitialized None N/A N/A
Continued