F.3.3.27 (ODU,ENABLE,1:1,CSAT#1,CONFIG, MISCELLANEOUS,LNA)
STATE
(ODU,ENABLE,1:1,CSAT#2,CONFIG, MISCELLANEOUS,LNA)
STATE
(ODU,ENABLE,STAND-ALONE,CONFIG,MISCELLANEOUS,LNA)
STATE
ODU LNA State:
On Off ( ,ENT)
The user is prompted to select either On or Off, using the arrow keys, then to press
ENT. This controls whether or not the CSAT will provide LNA POWER via the Receive
RF Cable.
F.3.3.28 (ODU,ENABLE,1:1,CSAT#1,CONFIG, MISCELLANEOUS,LNA)
CURR-WINDOW
(ODU,ENABLE,1:1,CSAT#2,CONFIG, MISCELLANEOUS,LNA)
CURR-WINDOW
(ODU,ENABLE,STAND-ALONE,CONFIG,MISCELLANEOUS,LNA)
CURR-WINDOW
LNA Current Window:
99 % ( ,ENT)
The user is prompted to edit the Current Window setting using the arrow keys, then
to press ENT. The value will scroll between 20% and 50% to define the allowable LNA
current change before declaring a fault. Selecting 99% disables the LNA Current
Window function.
F.3.3.29 (ODU,ENABLE,1:1,CSAT#1,CONFIG, MISCELLANEOUS,LNA)
CAL (Calibrate)
(ODU,ENABLE,1:1,CSAT#2,CONFIG, MISCELLANEOUS,LNA)
CAL (Calibrate)
(ODU,ENABLE,STAND-ALONE,CONFIG,MISCELLANEOUS,LNA)
CAL (Calibrate)
Calibrate LNA Current?
Cal Exit ( ,ENT)
The user is prompted to select either Cal or Exit, using the arrow keys, then to
press ENT. This provides a means to calibrate the LNA current for use with the Current-
Window function described previously.