2. System Reference
BX-220 User’s manual
11
Table 2.2. Installation Environment Requirements
Model
BX-220D-DC7xxxxx
Ambient
specifications
*4
0 - 50°C (When using 1000BASE-T : 0 - 45°C)
-10 - 60°C
Humidity
10 - 90%RH (No condensation)
Floating dust particles
Not to be excessive
Line-noise
resistance
Line noise
AC line / ±2kV *5,
Signal line / ±1kV (IEC61000-4-4 Level 3, EN61000-4-4 Level 3)
Static
electricity
Contact discharge / ±4kV (IEC61000-4-2 Level 2, EN61000-4-2 Level 2)
Atmospheric discharge / ±8kV (IEC61000-4-2 Level 3, EN61000-4-2 Level 3)
Vibration
resistance
Sweep
resistance
10 - 57Hz/semi-amplitude 0.375 mm 57 - 500Hz/5.0G
60 min. each in x, y, and z directions
(JIS C60068-2-6compliant, IEC68-2-6-compliant)
Impact resistance
100G, half-sine shock for 6 ms in x, y, and z directions
(JIS C0041-compliant, IEC68-2-27-compliant)
Class D grounding, SG-FG / continuity
*4 : For more details on this, please refer to chapter 3, “Installation Requirements”.
*5 : When AC adapter “ACAP19-01” is used.
Power Management Features
- Support both ACPI (Advanced Configuration and Power Interface) .
- ACPI v2.0 compliant
- Hardware automatic wake-up