- 88 -
-
-
-
C
C
C
C hapter13
hapter13
hapter13
hapter13 NIBP
NIBP
NIBP
NIBP Monitoring
Monitoring
Monitoring
Monitoring
13.1
13.1
13.1
13.1 Introduction
Introduction
Introduction
Introduction
Reference to the European standard EN 1060-1 : Specification for Non-invasive
sphygmomanometers Part 1, General requirements.
The Non-invasive Blood Pressure (NIBP) module measures the blood pressure using the
oscillometric method.
It is applicable for adult, pediatric, and neonatal usage.
There are three modes of measurement available: manual, automatic and continuous. Each mode
displays the diastolic, systolic and mean blood pressure.
In the MANUAL mode, only one measurement is conducted for each time .
In the AUTO mode, the measurement is cycled; you can set the interval time to
1/2/3/4/5/10/15/30/60/90 /120/180/240/480 minutes.
In the continuous mode, the monitor measures the blood pressure as many times as possible
in five minutes.
Warning
Warning
Warning
Warning
1.
1.
1.
1. You
You
You
You must
must
must
must not
not
not
not perform
perform
perform
perform NIBP
NIBP
NIBP
NIBP measurements
measurements
measurements
measurements on
on
on
on patients
patients
patients
patients with
with
with
with sickle-cell
sickle-cell
sickle-cell
sickle-cell disease
disease
disease
disease or
or
or
or under
under
under
under any
any
any
any
condition
condition
condition
condition which
which
which
which the
the
the
the skin
skin
skin
skin is
is
is
is damaged
damaged
damaged
damaged or
or
or
or expected
expected
expected
expected to
to
to
to be
be
be
be damaged.
damaged.
damaged.
damaged.
2.
2.
2.
2. For
For
For
For a
a
a
a thrombasthemia
thrombasthemia
thrombasthemia
thrombasthemia patient,
patient,
patient,
patient, it
it
it
it is
is
is
is important
important
important
important to
to
to
to determine
determine
determine
determine whether
whether
whether
whether measure
measure
measure
measure ment
ment
ment
ment of
of
of
of the
the
the
the blood
blood
blood
blood
pressure
pressure
pressure
pressure shall
shall
shall
shall be
be
be
be done
done
done
done automatically.
automatically.
automatically.
automatically. The
The
The
The determination
determination
determination
determination should
should
should
should be
be
be
be based
based
based
based on
on
on
on the
the
the
the clinical
clinical
clinical
clinical
evaluation.
evaluation.
evaluation.
evaluation.
3.
3.
3.
3. Ensure
Ensure
Ensure
Ensure that
that
that
that the
the
the
the correct
correct
correct
correct setting
setting
setting
setting is
is
is
is selected
selected
selected
selected when
when
when
when performing
performing
performing
performing measurements
measurements
measurements
measurements on
on
on
on children.
children.
children.
children. It
It
It
It
may
may
may
may be
be
be
be dangerous
dangerous
dangerous
dangerous for
for
for
for the
the
the
the children
children
children
children to
to
to
to use
use
use
use an
an
an
an over
over
over
over pressure
pressure
pressure
pressure level.
level.
level.
level.
13.2
13.2
13.2
13.2 NIBP
NIBP
NIBP
NIBP Monitoring
Monitoring
Monitoring
Monitoring
13.2.1
13.2.1
13.2.1
13.2.1 NIBP
NIBP
NIBP
NIBP Measuring
Measuring
Measuring
Measuring
Warning
Warning
Warning
Warning
Before
Before
Before
Before starting
starting
starting
starting a
a
a
a measurement,
measurement,
measurement,
measurement, verify
verify
verify
verify that
that
that
that you
you
you
you have
have
have
have selected
selected
selected
selected a
a
a
a setting
setting
setting
setting appropriate
appropriate
appropriate
appropriate for
for
for
for your
your
your
your
patient
patient
patient
patient (adult,
(adult,
(adult,
(adult, pediatric
pediatric
pediatric
pediatric or
or
or
or neonate.)
neonate.)
neonate.)
neonate.)
Do
Do
Do
Do not
not
not
not apply
apply
apply
apply the
the
the
the cuff
cuff
cuff
cuff to
to
to
to a
a
a
a limb
limb
limb
limb that
that
that
that has
has
has
has an
an
an
an intravenous
intravenous
intravenous
intravenous infusion
infusion
infusion
infusion or
or
or
or catheter
catheter
catheter
catheter in
in
in
in place.
place.
place.
place. This
This
This
This
could
could
could
could cause
cause
cause
cause tissue
tissue
tissue
tissue damage
damage
damage
damage around
around
around
around the
the
the
the catheter
catheter
catheter
catheter when
when
when
when infusion
infusion
infusion
infusion is
is
is
is slowed
slowed
slowed
slowed or
or
or
or blocked
blocked
blocked
blocked during
during
during
during
cuff
cuff
cuff
cuff inflation.
inflation.
inflation.
inflation.
Warning
Warning
Warning
Warning
Make
Make
Make
Make sure
sure
sure
sure that
that
that
that the
the
the
the air
air
air
air conduit
conduit
conduit
conduit connecting
connecting
connecting
connecting the
the
the
the blood
blood
blood
blood pressure
pressure
pressure
pressure cuff
cuff
cuff
cuff and
and
and
and the
the
the
the monitor
monitor
monitor
monitor is
is
is
is neither
neither
neither
neither
blocked
blocked
blocked
blocked nor
nor
nor
nor tangled.
tangled.
tangled.
tangled.
1. Plug in the air hose and switch on the system.
2. Apply the blood pressure cuff to the patient's arm or leg following the instructions below (Figure

Other manuals for Contec CMS8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Contec CMS8000 and is the answer not in the manual?

Contec CMS8000 Specifications

General IconGeneral
CategoryMedical Equipment
Device NameContec CMS8000
TypePatient Monitor
ECG Lead Mode3-lead or 5-lead
Resolution800 x 600
Power SupplyAC 100-240V, 50/60Hz
BatteryRechargeable lithium battery
Operating Temperature5°C to 40°C
Storage Temperature-20°C to 55°C
DisplayTFT LCD
Screen Size12.1 inches
ParametersECG, RESP, NIBP, SpO2, TEMP, PR
InterfaceEthernet, Nurse call
Humidity15% to 95% non-condensing
Battery LifeApproximately 4 hours

Related product manuals