- 97 -
-
-
-
Pneum test over pneumatic test over
Resetting... NIBP module in resetting
Reset failed NIBP module r eset failed
13.5
13.5
13.5
13.5 Maintenance
Maintenance
Maintenance
Maintenance and
and
and
and Cleaning
Cleaning
Cleaning
Cleaning
Warning
Warning
Warning
Warning
Do
Do
Do
Do not
not
not
not squeeze
squeeze
squeeze
squeeze the
the
the
the rubber
rubber
rubber
rubber tube
tube
tube
tube on
on
on
on the
the
the
the cuff.
cuff.
cuff.
cuff.
Do
Do
Do
Do not
not
not
not allow
allow
allow
allow liquid
liquid
liquid
liquid to
to
to
to enter
enter
enter
enter the
the
the
the connector
connector
connector
connector socket
socket
socket
socket at
at
at
at the
the
the
the front
front
front
front of
of
of
of the
the
the
the monitor.
monitor.
monitor.
monitor.
Do
Do
Do
Do not
not
not
not wipe
wipe
wipe
wipe the
the
the
the inner
inner
inner
inner part
part
part
part of
of
of
of the
the
the
the connector
connector
connector
connector socket
socket
socket
socket when
when
when
when cleaning
cleaning
cleaning
cleaning the
the
the
the monitor.
monitor.
monitor.
monitor.
When
When
When
When the
the
the
the reusable
reusable
reusable
reusable cuff
cuff
cuff
cuff is
is
is
is not
not
not
not connected
connected
connected
connected with
with
with
with the
the
the
the monitor,
monitor,
monitor,
monitor, or
or
or
or being
being
being
being cleaned,
cleaned,
cleaned,
cleaned, always
always
always
always place
place
place
place
the
the
the
the cover
cover
cover
cover on
on
on
on the
the
the
the rubber
rubber
rubber
rubber tube
tube
tube
tube to
to
to
to avoid
avoid
avoid
avoid liquid
liquid
liquid
liquid permeation.
permeation.
permeation.
permeation.
Reusable
Reusable
Reusable
Reusable Blood
Blood
Blood
Blood Pressure
Pressure
Pressure
Pressure Cuff
Cuff
Cuff
Cuff
The cuff can be sterilized by means of conventional autoclaving, gas, or radiation sterilization in hot air
ovens or disinfected by immersion in decontamination solutions, but remember to remove the rubber
bag if you use this method. The cuff should not be dry-cleaned.
The cuff can also be machine-washed or hand-washed, the latter method may prolong the service life
of the cuff. Before washing, remove the latex rubber bag, and for machine-washing, close the Velcro
fastening. Allow the cuff to dry thoroughly after washing, then reinsert the rubber bag.
Figure
Figure
Figure
Figure 13-
13-
13-
13- 5
5
5
5 Replace
Replace
Replace
Replace Rubber
Rubber
Rubber
Rubber Bag
Bag
Bag
Bag in
in
in
in Cuff
Cuff
Cuff
Cuff
To
replace the rubber bag in the cuff, first place the bag on top of the cuff so that the rubber tubes line
up with the large opening on the long side of the cuff. Now roll the bag lengthwise and insert it into the
opening on the long side of the cuff. Hold the tubes and the cuff and shake the complete cuff until the
bag is in position. Thread the rubber tubes from inside the cuff, and out through the small hole under
the internal flap.
Disposable
Disposable
Disposable
Disposable Blood
Blood
Blood
Blood Pressure
Pressure
Pressure
Pressure Cuffs
Cuffs
Cuffs
Cuffs
Disposable cuffs are intended for one-patient use only. Do not use the same cuff on any other patient.

Other manuals for Contec CMS8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Contec CMS8000 and is the answer not in the manual?

Contec CMS8000 Specifications

General IconGeneral
CategoryMedical Equipment
Device NameContec CMS8000
TypePatient Monitor
ECG Lead Mode3-lead or 5-lead
Resolution800 x 600
Power SupplyAC 100-240V, 50/60Hz
BatteryRechargeable lithium battery
Operating Temperature5°C to 40°C
Storage Temperature-20°C to 55°C
DisplayTFT LCD
Screen Size12.1 inches
ParametersECG, RESP, NIBP, SpO2, TEMP, PR
InterfaceEthernet, Nurse call
Humidity15% to 95% non-condensing
Battery LifeApproximately 4 hours

Related product manuals