5 Maintenance
Operator manual: Postmix tower
Ribbon
44
Cornelius Deutschland GmbH
Document no. TD0000000
Version: 19/10/2017, Index 3
9. Clean the nozzle housing with warm water and a brush.
10. Clean the diffusor and diffusor seal with warm water and
a brush.
11. Remove the grill from the drip tray.
12. Remove the drip tray from the unit.
13. Check if there is a drain set (accessory) installed.
– If there is no drain set (accessory) installed, proceed
with step 14, page 45.
– If there is a drain set (accessory) installed, remove it
as follows:
a. Undo the tubing clamp (Figure 67/2) and
remove the tube (Figure 67/3) from the drain fit-
ting (Figure 67/1).