EasyManua.ls Logo

Curtis 1222 - Page 113

Curtis 1222
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Curtis 1222 Manual, os 15
109
2 9 J A N U A R Y 2 0 1 3 D R A F T
7 — DIAGNOSTICS & TROUBLESHOOTING
Table 6 TROUBLESHOOTING CHART, continued
FLASH SUB
CLEAR STEER TRACTION
CODE CODE
NAME
POSSIBLE CAUSE
SET CONDITION
CONDITION
FAULT ACTION
FAULT ACTION
75 1 Parameter 1. Parameter settings are in conflict 1. Command Input Device = 1 and Vehicle Cycle KSI. Shutdown. 1 = Stop.
Conflict with each other. Configuration » Traction Speed Input »
2. Parameter setting out of range. Input Type = 1.
2. Vehicle Configuration » Nominal Voltage
is out of range (24–48 V).
3. Motor Control Tuning » Motor Type
is out of range (0–22).
4. Motor » Temperature Control » Sensor
Type is out of range (0–5).
5. Command Input Device » 0-Analog1 and
3 » Analog1 Left, Center, and Right must
be in ascending or descending order.
6. Command Input Device » 0-Analog1 and
3 » Analog3 Left, Center, and Right must
be in ascending or descending order.
7. Feedback Device » 0-Analog5 and
6 » Analog5 Left Stop, Center, and Right
Stop must be in ascending or descending
order.
8. Feedback Device » 0-Analog5 and
6 » Analog6 Left Stop, Center, and Right
Stop must be in ascending or descending
order.
9. Command Device » Command Map »
Left Stop (deg) or Right Stop (deg) = 0.

Table of Contents