Curtis 1222 Manual, os 15
109
2 9 J A N U A R Y 2 0 1 3 D R A F T
7 — DIAGNOSTICS & TROUBLESHOOTING
Table 6 TROUBLESHOOTING CHART, continued
FLASH SUB
CLEAR STEER TRACTION
CODE CODE
NAME
POSSIBLE CAUSE
SET CONDITION
CONDITION
FAULT ACTION
FAULT ACTION
75 1 Parameter 1. Parameter settings are in conflict 1. Command Input Device = 1 and Vehicle Cycle KSI. Shutdown. 1 = Stop.
Conflict with each other. Configuration » Traction Speed Input »
2. Parameter setting out of range. Input Type = 1.
2. Vehicle Configuration » Nominal Voltage
is out of range (24–48 V).
3. Motor Control Tuning » Motor Type
is out of range (0–22).
4. Motor » Temperature Control » Sensor
Type is out of range (0–5).
5. Command Input Device » 0-Analog1 and
3 » Analog1 Left, Center, and Right must
be in ascending or descending order.
6. Command Input Device » 0-Analog1 and
3 » Analog3 Left, Center, and Right must
be in ascending or descending order.
7. Feedback Device » 0-Analog5 and
6 » Analog5 Left Stop, Center, and Right
Stop must be in ascending or descending
order.
8. Feedback Device » 0-Analog5 and
6 » Analog6 Left Stop, Center, and Right
Stop must be in ascending or descending
order.
9. Command Device » Command Map »
Left Stop (deg) or Right Stop (deg) = 0.