50
Curtis 1222 Manual, os 15
2 9 J A N U A R Y 2 0 1 3 D R A F T
3 — PROGRAMMABLE PARAMETERS: Motor Parameters
MOTOR: USER-DEFINED TEMPERATURE SENSOR
This menu contains 14 parameters (7 sensor-temperature pairs) which
define a 7-point map that is used to map the voltage input to a sensor
temperature profile.
This menu is used only when Motor Temperature Sensor Type = 0
(User-defined).
It is best to select one point near the Temperature Hot value so the
controller will accurately regulate motor temperature.
ALLOWABLE
PARAMETER RANGE DESCRIPTION
Sensor 1–7 0.0 – 10.0 V The seven Sensor parameters define inputs to the user-defined
see list 0 – 1023 temperature sensor map.
The units are in volts.
Sensor 1 = 0x4086 0x00
Sensor 2 = 0x4088 0x00
Sensor 3 = 0x408A 0x00
Sensor 4 = 0x408C 0x00
Sensor 5 = 0x408E 0x00
Sensor 6 = 0x4090 0x00
Sensor 7 = 0x4092 0x00
Temp 1–7 -60.0 – 250.0 °C The seven Temp parameters define outputs to the user-defined
see list -600 – 2500 temperature sensor map.
The units are in °C.
Temp 1 = 0x4087 0x00
Temp 2 = 0x4089 0x00
Temp 3 = 0x408B 0x00
Temp 4 = 0x408D 0x00
Temp 5 = 0x408F 0x00
Temp 6 = 0x4091 0x00
Temp 7 = 0x4093 0x00
PCF
RIS