COMMAND INPUT DEVICE 0 – ANALOG1 and 3
ALLOWABLE
PARAMETER RANGE DESCRIPTION
Analog1 Left 0 – 10.00 V
• n
Defines the Analog 1 wiper voltage required to produce a steer position
0x4008 0x00 0 – 1023 command of full left (Steer Command = -100% = Left Stop).
Analog1 Center 0 – 10.00 V
• n
Defines the Analog 1 wiper voltage required to produce a steer position
0x400A 0x00 0 – 1023 command of center (Steer Command = 0% = 0°).
Analog1 Right 0 – 10.00 V
• n
Defines the Analog 1 wiper voltage required to produce a steer position
0x4009 0x00 0 – 1023 command of full right (Steer Command = 100% = Right Stop).
Analog1 Fault Min 0 – 10.00 V Sets the minimum threshold for the Analog 1 steer command pot input.
0x400E 0x00 0–1023 If the Analog 1 steer command pot voltage goes below this threshhold for
60 ms, a fault is issued.
Analog1 Fault Max 0 – 10.00 V Sets the maximum threshold for the Analog 1 steer command pot input.
0x400F 0x00 0 – 1023 If the Analog 1 steer command pot voltage rises above this threshhold for
60 ms, a fault is issued.
Analog3 Left 0 – 10.00 V
• n
Defines the Analog 3 wiper voltage required to produce a steer position
0x409F 0x00 0 – 1023 command of full left (Steer Command = -100% = Left Stop).
Analog3 Center 0 – 10.00 V
• n
Defines the Analog 3 wiper voltage required to produce a steer position
0x40A1 0x00 0 – 1023 command of center (Steer Command = 0% = 0°).
Analog3 Right 0 – 10.00 V
• n
Defines the Analog 3 wiper voltage required to produce a steer position
0x40A0 0x00 0 – 1023 command of full right (Steer Command = 100% = Right Stop).
Analog3 Fault Min 0 – 10.00 V Sets the minimum threshold for the Analog 3 steer command pot input.
0x400B 0x00 0 – 1023 If the Analog 3 steer command pot voltage falls below this threshhold for
60 ms, a fault is issued.
Analog3 Fault Max 0 – 10.00 V Sets the maximum threshold for the Analog 3 steer command pot input.
0x400C 0x00 0 – 1023 If the Analog 3 steer command pot voltage rises above this threshhold for
60 ms, a fault is issued.
3 — PROGRAMMABLE PARAMETERS:
Command Input Parameters
PCF
RIS