14
Preliminary on Verso page is set with right edge at 7 and 7/8,
and the top (as on the Recto page) at 1/4.
14 1315161718192021222324
121110987654321
14 1315161718192021222324
121110987654321
+
-
B-
+
+
-
B-
+
SENSOR OUTPUT (05V)
J1
SENSOR
SENSOR GROUND
J1
SENSOR OUTPUT (05V)
SENSOR
Pot Low input (Pin 22)
Hyd. 0–5V input (Pin 21)
0–5V input (Pin 4)
Hyd. 0–5V input (Pin 21)
0–5V input (Pin 4)
Traction
Throttle
Hydraulic
Throttle
Traction
Throttle
Hydraulic
Throttle
Also, the controller recognizes the voltage between the wiper input and B- as the
applied throttle voltage and not the voltage from the voltage source relative to
the Pot Low input.
For either throttle input, if the 05V throttle input (Pin 4 or 21) exceeds
5.5V relative to B-, the controller will register a fault and shut down.
Fig. 6 Wiring for
0–5V throttles (“Type 2”).
(b) Ground-referenced
0–5V source
(a) Sensor-referenced
0–5V source