A-18
APPENDIX A: GLOSSARY
APPENDIX D
PROGRAMMABLE PARAMETERS
The 1297’s programmable parameters are listed below in alphabetical order (by display name), along with the
default access levels, minimum and maximum allowable values, and default settings that are standard on
generic models. Cross references to the main entry in the manual are also provided.
Not included in this alphabetical listing are the hourmeter and battery discharge indicator (BDI)
parameters, which are listed separately.
Table D-1 PARAMETER RANGES AND DEFAULT SETTINGS
(for Generic 1297 Controllers with Rev. 01 Software)
1297 DEFAULT MIN MAX DEFAULT DESCRIPTION
PARAMETER ACCESS VALUE VALUE SETTING UNITS IN
MANUAL
ACCEL RATE, M1-M2 OEM 0.1 3.0 0.5 seconds
page 24
ANTI-TIEDOWN OEM OFF —
page 44
BOOST ENABLE OEM OFF —
page 25
BRAKE C/L, M1-M2 OEM 50 RATED CURRENT*
1
RC*
1
amps
page 25
BRAKE RATE, M1-M2 OEM 0.1 3.0 0.5 seconds
page 26
COAST DECEL OEM 0.1 10.0 0.3 seconds
page 26
CREEP SPEED OEM 0 25 0 percent
page 31
CURRENT RATIO OEM 1 4 2 —
page 25
DECEL RATE, M1-M2 OEM 0.1 10.0 3.0 seconds
page 26
DRIVE C/L, M1-M2 OEM 50 RATED CURRENT*
1
RC*
1
amps
page 24
E-M BRAKE DLY OEM 0.0 30.0 3.0 seconds
page 29
E-M BRAKE TYPE OEM 0 5 1 —
page 29
EMR ACCEL RATE OEM 0.0 3.0 0.1 seconds
page 43
EMR DIR INT OEM ON —
page 43
EMR REV C/L OEM 50 RATED CURRENT*
1
RC*
1
amps
page 43
EMR REV CHECK OEM OFF —
page 43
EMR TIME LIMIT OEM OFF —
page 43
FIELD CHECK OEM ON —
page 42
FIELD MAP OEM 0 100 50 percent
page 41
FIELD MAX OEM FIELD MIN RATED CURRENT*
2
RC*
2
amps
page 41
FIELD MIN OEM 2.0 RESTRAINT 5.0 amps
page 41
FLD MAP START OEM 25 RATED CURRENT*
1
75 or 100 amps
page 41
H/S LATCH OEM OFF —
page 31
HPD OEM 0 2 1 —
page 44
HYD INHIBIT OEM OFF —
page 48
HYD THRTL DB OEM 0 40 10 percent
page 51
HYD THRTL MAP OEM 20.0 80.0 50.0 percent
page 54
D-1
APPENDIX D: PROGRAMMABLE PARAMETERS
*
1
The rated armature current for the traction motor depends on the controller model:
1297-22XX (150 amps), 1297-23XX (250 amps), 1297-24XX (350 amps);
the default setting is the maximum value.
*
2
The rated field current for the traction motor depends on the controller model:
1297-22XX (25 amps), 1297-23XX (25 amps), 1297-24XX (35 amps);
the default setting is the maximum value.