8 MAINTENANCE
8
MAINTENANCE
There are no user serviceable parts in the Curtis PMC 1297 controller. No
attempt should be made to open, repair, or otherwise modify the controller.
Doing so may damage the controller and will void the warranty.
It is recommended that the controller be kept clean and dry that its
diagnostics history le be checked and cleared periodically.
CLEANING
Periodically cleaning the controller exterior will help protect it against corrosion
and possible electrical control problems created by dirt, grime, and chemicals
that are part of the operating environment and that normally exist in battery
powered systems.
When working around any battery powered system, proper safety
precautions should be taken. These include, but are not limited to: proper
training, wearing eye protection, and avoiding loose clothing and jewelry.
Use the following cleaning procedure for routine maintenance. Never use
a high pressure washer to clean the controller.
1. Remove power by disconnecting the battery.
2. Discharge the capacitors in the controller by connecting a load
(such as a contactor coil) across the controllers B+ and B-
terminals.
3. Remove any dirt or corrosion from the power and signal connector
areas. The controller should be wiped clean with a moist rag.
Dry it before reconnecting the battery.
4. Make sure the connections are tight. Refer to Section 2, page 7,
for maximum tightening torque specications for the battery
and motor connections.
DIAGNOSTIC HISTORY
The 13XX programmer can be used to access the controllers diagnostic history
le. The programmer will read out all the faults the controller has experienced
since the last time the diagnostic history le was cleared. Faults such as contactor
faults may be the result of loose wires; contactor wiring should be carefully
checked. Faults such as overtemperature may be caused by operator habits or by
overloading.
After a problem has been diagnosed and corrected, it is a good idea to
clear the diagnostic history le. This allows the controller to accumulate a new
le of faults. By checking the new diagnostic history le at a later date, you can
readily determine whether the problem was indeed xed.
For instructions on accessing and clearing the diagnostic history le, see
the Curtis PMC 13XX programmer manual.