EasyManuals Logo

Curtis 1297 User Manual

Curtis 1297
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
Curtis PMC 1297 Manual
41
FIELD MIN
The minimum field current limit parameter denes the minimum allowed
eld winding current. The minimum eld current limit setting determines the
vehicles maximum speed. Field Min can be adjusted from 2 amps up to the
programmed Field Max value.
The Field Min parameter is tuned as part of the vehicle performance
adjustment process (Section 5).
FIELD MAX
The maximum field current limit parameter denes the maximum allowed
eld winding current. The maximum eld current limit setting determines the
vehicles maximum torque and limits the power dissipation in the eld winding
itself. Field Max can be adjusted from the programmed Field Min value up to
the controllers full rated eld current. (The full rated eld current depends on
the controller model; see specications in Table E-1.)
The Field Max parameter is tuned as part of the vehicle performance
adjustment process (Section 5).
FLD MAP START
The field map start parameter denes the armature current at which the eld
map starts to increase; it is adjustable from 25 amps up to the controllers full
rated armature current value. (The full rated armature current depends on the
controller model; see specications in Table E-1.)
The eld map start parameter is used to equalize the vehicles maximum
speed when loaded and unloaded. Increasing the eld map start parameter
value will increase the maximum load weight that the vehicle can carry while
maintaining maximum speed on a level surface.
The eld map start parameter is tuned as part of the vehicle performance
adjustment process (Section 5).
FIELD MAP
The field map parameter controls how much eld current is applied for a given
armature current. This parameter, along with the other eld current parameters
(Field Min, Field Max, and Field Map Start), allows the OEM to set the vehicles
speed and power performance characteristics.
The eld map parameter is set as a percentage of the eld current between
the Field Min and Field Max values. As shown in Figure 19, the eld map
parameter adjusts the eld current at a point halfway between the programmed
Field Map Start current and the full armature current (which is the controllers
3
A
PROGRAMMABLE TRACTION PARAMETERS: Field
Field Parameters

Table of Contents