EasyManua.ls Logo

Curtis 1297 - Page 116

Curtis 1297
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Curtis PMC 1297 Manual
A-19
APPENDIX A: GLOSSARY
HYD THRTL MAX OEM 60 100 90 percent
page 53
HYD THRTL TYPE OEM (see sidebox) 2
page 51
INT BRAKE C/L OEM 50 RATED CURRENT*
1
RC*
1
amps
page 27
INT BRAKE DLY OEM 0.0 30.0 2.0 seconds
page 27
INT BRAKE RATE OEM 0.0 3.0 0.1 seconds
page 27
INT OVERRIDE OEM OFF
page 31
LOAD COMP OEM 0.0 25.0 0.0 percent
page 32
LOAD HOLD DLY OEM 0.0 1.0 0.5 seconds
page 50
LV ACCEL OEM 0.0 3.0 0.1 seconds
page 49
LV CHECK OEM ON
page 50
LV DECEL OEM 0.0 3.0 0.1 seconds
page 50
LV DITHER OEM 0 100 0 percent
page 49
LV MAX C/L OEM LV MIN C/L 3.0 1.0 amps
page 49
LV MIN C/L OEM 0.0 LV MAX C/L 1.0 amps
page 49
MAIN CONT DIAG OEM ON
page 57
MAIN CONT INT OEM ON
page 57
MAIN OPEN DLY OEM 0 40 0 seconds
page 57
MAX SPEED, M1-M2 OEM CREEP SPEED 100 100 percent
page 31
MUX ENABLE OEM OFF
page 58
NO LOAD C/L OEM 0 PUMP C/L 0 amps
page 46
NO LOAD SPEED OEM 0 100 100 percent
page 46
POT LOW CHECK OEM OFF
page 40
PUMP ACCEL OEM 0.1 3.0 0.1 seconds
page 47
PUMP BDI L/O OEM OFF
page 48
PUMP BDI WARN OEM OFF
page 48
PUMP C/L OEM 25 RATED CURRENT*
3
RC*
3
amps
page 46
PUMP DECEL OEM 0.1 3.0 0.1 seconds
page 47
PUMP LOCK C/L OEM 25 RC*
3
+50 RC*
3
amps
page 48
PUMP LOCK DLY OEM 0.1 25.0 0.5 seconds
page 48
PUMP MAX SPEED OEM 0 100 100 percent
page 46
RESTRAINT OEM FIELD MIN RATED CURRENT*
2
5.0 or 8.0 amps
page 27
SEQUENCING DLY OEM 0.0 3.0 0.1 seconds
page 57
SRO OEM 0 3 0
page 45
TAPER RATE OEM 1 20 10
page 26
THROTTLE DB OEM 0 40 10 percent
page 34
THROTTLE DECEL OEM 0.1 1.0 0.3 seconds
page 26
THROTTLE MAP OEM 20.0 80.0 50.0 percent
page 38
THROTTLE MAX OEM 60 100 90 percent
page 36
THROTTLE TYPE OEM (see sidebox††) 2
page 33
VARIABLE BRAKE OEM ON
page 28
VARIABLE LIFT OEM OFF
page 56
VARIABLE LOWER OEM OFF
page 56
1297 DEFAULT MIN MAX DEFAULT DESCRIPTION
PARAMETER ACCESS VALUE VALUE SETTING UNITS IN
MANUAL
Table D-1, continued
D-2
APPENDIX D: PROGRAMMABLE PARAMETERS
†† Traction
throttle
types:
1=5k–0
2=0–5V
3=0–5k
4=wigwag
Hydraulic
throttle
types:
2=0–5k
4=0-5V
*
3
The rated armature current for the pump motor depends on the controller model:
1297-22XX (200 amps), 1297-23XX (200 amps), 1297-24XX (300 amps);
the default setting is the maximum value.

Table of Contents