3.10 -
Pressurization and Air Conditioning
PRESSU OFF 1 / 2
Possibly due to:
- system malfunction,
- BLEED switch in OFF/RST position.
If in flight:
If airplane altitude is > 10,000 ft:
1
- Oxygen masks ..................................................................... Use
Refer to procedure
Oxygen Use in Subsection
3.13.
2 - BLEED switch ....................................................................... OFF/RST
3 - CPCS PWR1 and CAB BLEED (ESS BUS 2) breakers ........... Check
pushed
4 - CPCS PWR2 (BUS 2) breaker ..................................... Check pushed
If possible:
5 - TRQ ................................................................................. Reduce
Fly the airplane ◄
6 - BLEED switch ............................................................................ AUTO
Continue ►
Pilot's Information Manual
Section 3
Emergency Procedures
PIM TBM 960 - Edition 0
Rev. 00
Page 3.10.1
PIM - DO NOT USE FOR FLIGHT OPERATIONS