After Engine Start 1 / 2
CAUTION
Generator load < 200 A.
1 - THROTTLE ............................................................................................. IDLE
For 2 minutes
2 - Ng
......................................................................................................... Check
NOTE
In ISA conditions at sea level, Ng ≈ 58.5%.
Ng may vary between 55% and 63% depending on external conditions.
3 - OIL °C and OIL PSI .............................................................................. Check
4 - AUX BP
switch .......................................................................... Check AUTO
5 - FUEL SEL pushbutton .......................................................................... AUTO
Status light in blue
6 - SHIFT pushbutton .................................................................................... Test
Verify rotation of FUEL TANK SELECTOR
7 - AP/TRIMS switch ...................................................................... ON / Test OK
This initializes the AP and AT systems
8 - PFD 1, MFD and PFD 2 ........................................................ NORMAL mode
Perform generator test.
9 - GENERATOR selector ...................................................... Check MAIN
10 - AMPS / VOLTS ............................................................................ Check
When MAIN LOAD < 80 A:
11 - GENERATOR selector ....................................................... ST-BY
To perform test
12 - AMPS / VOLTS .................................................................. Check