Maximum Cruise Power
NOTE The following table provides references to torque tables that should be
used depending on INERT SEP ON/OFF status and bleed status.
In the table below:
- Bleed status "P2.5" = P2.5 HI and P3 messages are OFF,
- Bleed status "P2.5 HI or P3" = P2.5 HI or P3 message is ON.
Table 5.8.19 - References to MXCR Torque Tables
INERT SEP Bleed status FL < 200 FL > 200
OFF
P2.5 Table 5.8.20 Table 5.8.21
P2.5 HI or P3 Table 5.8.22 Table 5.8.23
ON
P2.5 Table 5.8.24 Table 5.8.25
P2.5 HI or P3 Table 5.8.26 Table 5.8.27
Section 5
Performance
Pilot's Information Manual
PIM TBM 960 - Edition 0
Rev. 01
Page 5.8.36