BAT OFF 1 / 1
Indicates that:
- the SOURCE selector has been positioned on OFF, or
- the battery plug is disconnected.
Fly the airplane ◄
1 - SOURCE selector .................................................................................. OFF
2 - SOURCE selector ................................................................................ BATT
If warning persists:
Land as soon as possible ◄
3 - Airplane mains voltage ....................................................................... Monitor
End of procedure.
Pilot's Information Manual
Section 3A
Abnormal Procedures
PIM TBM 960 - Edition 0
Rev. 00
Page 3A.9.2