MAIN GEN and LOW VOLTAGE 1 / 3
With GENERATOR selector on ST-BY (after MAIN generator failure), functioning
on ST-BY generator.
1 - GENERA
TOR selector ........................................................................... MAIN
2 - MAIN GENERATOR RESET pushbutton .............................................. Press
Fly the airplane ◄
If MAIN GENERATOR successfully connected:
3 - Disconnect non-essential systems.
4 - Voltmeter and ammeter ............................................................. Monitor
Land as soon as possible ◄
End of procedure ■
If MAIN GENERATOR not successfully connected:
5 - GENERATOR selector ................................................................ ST-BY
6 - ST-BY GENERATOR RESET pushbutton .................................... Press
If ST-BY GENERATOR successfully connected:
7 - Disconnect non-essential systems.
8 - Voltmeter and ammeter .................................................... Monitor
Land as soon as possible ◄
End of procedure ■
If ST-BY GENERATOR not successfully connected:
Both generators failure is confirmed.
Return to VMC conditions, if possible.
9 - GENERATOR selector .......................................................... OFF
If airplane altitude is > 10,000 ft:
10 - OXYGEN switch ............................................................. ON
Continue ►