Engine Start 1 / 2
CAUTION
After aborted engine starts, wait:
1 minute / 5 minutes / 30 minutes before 2nd / 3rd / 4th new engine start.
1 - THROTTLE ............................................................................................. IDLE
2 - IGNITION ...................................................................................
Check AUTO
3 - ENGINE MODE ..................................................................... RUN / Guarded
4 - AUX BP ................................................................................................ AUTO
5 -
AUX BP ON .................................................................................. Check ON
6 - Propeller area ........................................................................................ Clear
7
- STARTER .................................................................................................. ON
2 seconds, then release
8 - ITT, Ng, OIL °C and OIL PSI .............................................................. Monitor
Aborting start procedure:
If ITT > 850 °C:
Manually abort the start sequence as follows:
9 - STARTER ......................................................................... ABORT
2 seconds, then release
CAUTION
Do not attempt another engine start after automatic or manual aborted
start, except if the previous start sequence was aborted due to:
- low battery voltage,
- FUEL TANK SELECTOR in the OFF
position, or
- other than engine-related reason.
For all other cases, the airplane is grounded. Inform maintenance
department.
End of procedure ■