Defog Malfunction 1 / 1
NOTE
The demisting function is automatically switched OFF 10 minutes after the
DEFOG pushbutton has been set to ON.
If moisture starts to quickly cover the inside of the windscreen with the DEFOG
pushbutton already ON (status light in green):
1 - DEFOG pushbutton .............................................................
Press twice
Status light in green
If moisture continues:
2 - DE ICE SYSTEM mode switch ............................................. MAN
All deicing systems turn on
3 - WINDSHIELD pushbutton ............................................ Check ON
Status light in green
If there is no improvement and if the flight safety is engaged:
4 - Altitude ........................................................ Below 10,000 ft
5 - BLEED switch ...................................................... OFF/RST
CAUTION
In flight, the cabin will quickly depressurize. Therefore, the cabin vertical
speed indicator and altimeter indications will rapidly meet those of
respectively the airplane VSI and altimeter.
End of procedure.
Pilot's Information Manual
Section 3A
Abnormal Procedures
PIM TBM 960 - Edition 0
Rev. 00
Page 3A.10.5
PIM - DO NOT USE FOR FLIGHT OPERATIONS