3A.11 -
Deicing System
AFRM DEICE FAIL 1 / 1
Symptoms: failure on one of the two pneumatic deicing pulses:
- ice on wing outboard sections,
- or, ice on wing inboard sections and stabilizers,
- AIRFRAME DE ICE status light lit in red.
Leave icing conditions as soon as possible ◄
1 - DE ICE SYSTEM mode switch ............................................................... MAN
All deicing systems turn on
2 - AIRFRAME DE ICE pushbutton .............................................................. OFF
Status light in white
End of procedure.