EasyManua.ls Logo

Daher TBM 960 - Utilization in Cold Weather (0 °C to -25 °C) and very Cold Weather (-25 °C to -40°C)

Daher TBM 960
957 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Utilization in Cold Weather (0 °C to -25 °C) and Very Cold Weather
(-25 °C to -40°C)
1 /
1
NOTE
The procedure hereafter supplements the normal procedures for the airplane
use when operating under temperatures between 0 °C and -40 °C on ground.
Figure 4.5.1 - Operating Envelopes in Cold Weather (0 °C to -25°C) and Very Cold
Weather (-25°C to -40 °C)
C4010000AAAAMA8000
- 20
- 40
- 30
- 10
0
10
0
2
3
4
5
6
7
8
9
10
OAT (°C)
Normal
procedures
ENVELOPE 1
Normal procedures
ENVELOPE 3
GPU starting
Systems heating
Cabin
preheating +
Systems heating
ENVELOPE 2
Transit
time
(hours)
OPERATING ENVELOPES
BAT starting
GPU starting
1
End of procedure.